Why envelope analysis finds bearing faults before RMS does

A bearing that fails without warning stops its machine, and often the whole line, until a new one is fitted. On a test rig at the University of Cincinnati, a bearing ran for three days with a growing defect on its outer ring while its overall vibration velocity, the figure severity charts rate machines by, stayed close to its first-day level. Read with envelope analysis, the same recordings flagged the defect at the start of those three days.

Envelope analysis of bearing vibration listens to the faint ringing that each impact of a damaged bearing sets off, and turns it into the rhythm of the impacts, which names the damaged part. This post applies the method to the rig's recordings, which NASA publishes for anyone to check, and four things came out:

  • The envelope warned first wherever the recordings show the fault. It flagged the outer-ring defect 28 hours before overall acceleration doubled and 3 days before overall velocity did. Whether and how much earlier depends on where each alarm is set: with a more sensitive overall alarm, overall acceleration came first on an inner-ring failure of the same rig.
  • Overall vibration hides early damage because the impacts carry little energy. At the 100th hour the outer ring's rhythm was 11 times stronger than on the first day, while overall acceleration had risen 18% and velocity 3%.
  • A warning needs a rhythm that stands out clearly, not just one that grows, because a weak rhythm can double by chance.
  • The envelope tells which fault, not how bad it is, and the sensor on a healthy neighbor on the same shaft can pick up the rhythm first.

These numbers come from three runs of one rig, which turned four identical bearings on one shaft at a constant 2,000 rpm. They show how early the envelope can see and where it misleads, not how early it will see on your machine.

Maintenance and reliability engineers get the method, a bearing fault frequency calculator and a warning rule for their own system. Managers who buy a vibration monitoring system get four questions that show whether it can see a bearing fault early. Our post on measuring a machine's natural frequency from video covers what a camera measures in place of a sensor.

A failing bearing knocks, and overall vibration barely notices

Many vibration monitoring systems raise their alarm on the overall vibration, which sums up each recording in one number. It is an RMS value, short for root mean square, a kind of average of how strongly the bearing housing shakes over the recording. Systems take it from acceleration or from velocity, and velocity is the number the ISO severity zones for industrial machines are written in.

A small defect on a bearing ring adds little to the overall value. Each time a roller passes the defect it strikes the edge, and the housing rings like a bell for about a millisecond at several thousand hertz. Hundreds of such knocks a second carry little energy next to the running machine, so the average hardly rises.

Bearing 1's outer-ring rhythm and its overall vibration over the seven days of the run
Bearing 1 of the rig's second run failed at the outer ring. The ink line follows the outer ring's rhythm from envelope analysis, and the grey lines overall acceleration and overall velocity, each as a multiple of its first day, one point an hour. The envelope line starts near 1.5 because single recordings are noisier than the first day's average. The dotted line marks the warning level, and the circles mark when each warning came. Measured.

Bearing 1 of the rig's second run shows the gap. The outer ring's rhythm in the envelope doubled 3.7 days into the run. Overall acceleration passed the same line at 4.9 days, and overall velocity at 6.8 days, 40 minutes before the run ended.

Overall vibration is not the wrong number, only a late one for this kind of damage. As the damage spreads, the knocks blur into broad noise that raises the overall level, and their rhythm can fade. The next sections show what sets their rhythm, how the envelope spectrum finds it, and what to do.

Each bearing fault frequency is set by the bearing's dimensions

A rolling bearing has four parts, and a defect on each one makes knocks at its own rate, set by the shaft speed, the number of rolling elements, their diameter, the pitch diameter (the circle their centers run on) and the contact angle. These rates are the bearing fault frequencies, also called bearing defect frequencies:

  • Outer ring, or outer race: usually stands still, and the rolling elements run around its inside. Every pass strikes a defect on it equally hard. BPFO, ball pass frequency outer race, is how often an element passes one spot on it.
  • Inner ring, or inner race: sits on the shaft and turns with it, so its rate, BPFI, ball pass frequency inner race, is higher. A defect on it is struck hardest on the bearing's loaded side, so its knocks grow and fade once a turn.
  • Rolling elements: balls or rollers that roll between the rings. BSF, ball spin frequency, is how fast each spins about its own axis, and a damaged element's rhythm is twice the BSF.
  • Cage: turns with the rolling elements at FTF, fundamental train frequency, which is a little under half the shaft speed.
The parts of a rolling bearing, each named with the rhythm of a defect on it, and the dimensions the formulas use
The drawing shows a ball bearing from the front, each part named with the fault frequency of a defect on it, and the pitch circle. Below it, one rolling element is cut along the shaft, with its diameter d and the contact angle α at which the rings press on it. The rig's bearings are double-row roller bearings with the same four parts. An illustration, not to scale.

The contact line runs through the points where an element touches the two rings, and the contact angle is its tilt from a line at right angles to the shaft. A larger angle lets a bearing take more load along the shaft and less across it. Take the angle from the maker's data: on the rig's bearing, leaving it out would move each fault frequency by less than half a percent.

A spectrum splits a vibration into the frequencies it contains, each shown as a line as tall as that frequency is strong. None of the fault frequencies is a whole multiple of the shaft speed, so a line at one of them is the bearing's and not the shaft's. The calculator works them out from a bearing's dimensions, starting with the rig's bearing: 16 rollers a row at 2,000 rpm give a BPFO of 236.4 Hz.

Bearing fault frequency calculator

Enter the shaft speed and the bearing's dimensions from its maker's data. Both diameters in the same unit, any unit.

Outer ring, BPFOHz × shaft speed
Inner ring, BPFIHz × shaft speed
Rolling element, 2 × BSFHz × shaft speed
Cage, FTFHz × shaft speed

Shaft speed Hz. Filled in with the test rig's bearing: 16 rollers a row, roller diameter 0.331 in, pitch diameter 2.815 in, contact angle 15.17°, at 2,000 rpm. The formulas assume the elements roll without slipping, so look for each line in a narrow window around it.

The formulas describe elements that roll without slipping, so real lines sit a little off the calculated ones: look for each one in a narrow window around its calculated value. In the ordinary spectrum, though, the knocks are buried under the running machine, and the envelope spectrum brings them out.

The envelope spectrum turns the ringing into the knocks' rhythm

The knocks are hidden twice over: they are faint next to the running machine, and their sound sits thousands of hertz above their rhythm. Envelope analysis brings them out of one recording in three steps:

  1. Filter the recording to the band where the housing rings, a few kilohertz, which leaves out the running machine below it.
  2. Take the envelope, the curve over the ringing's peaks, which rises at each knock and falls between them.
  3. Compute the envelope's spectrum. Its lines sit at the knocks' rhythm and its multiples, where the calculator puts them.

The filter takes away the running machine, and the envelope brings the ringing down to the knocks' rhythm. The running machine shakes mostly at low frequencies, such as its shaft speed, while the knocks' ringing reaches far above them, so in the filtered band the knocks are much of what is left. The envelope then rises once per knock, so the energy of each knock's ringing, spread over thousands of hertz, comes back at the knocks' rhythm. Its spectrum gathers that energy into a few tall lines, which the ordinary spectrum spreads thin.

The ringing of one recording and its envelope, with a mark every 4.23 milliseconds
The grey line is 40 milliseconds of bearing 1's recording at the 100th hour of the rig's second run, filtered to the band where the housing rings, and the ink line is its envelope. The marks above start at the first knock and come every 4.23 ms, which is the outer ring's rhythm of 236.4 knocks a second. Measured.

At the 100th hour of the rig's second run, the ordinary spectrum barely changed at the outer ring's rhythm, where any change is lost among the machine's own lines. The envelope spectrum showed that rhythm and its multiples about 11 times stronger than on the first day.

The ordinary spectrum and the envelope spectrum, first day and 100th hour
Both panels show bearing 1 of the rig's second run on the first day (grey) and at the 100th hour (ink). The velocity spectrum is on top and the envelope spectrum below, each on its own scale, and the dotted lines mark the outer ring's rhythm, BPFO, and twice and three times it. Measured.

An envelope line shows that a rhythm is there, not how deep the damage is. The method works poorly on motors fed by variable frequency drives (VFDs), on reciprocating machines and on commutator motors, whose own high-frequency noise drowns the knocks.

For a trend, keep the sensor where it is and the band fixed, and avoid a band on one sharp ringing of the housing, where the level follows the housing more than the bearing. A monitoring system also needs a rule for when a line counts as a warning, and the last section's steps set one up.

Where to start and what to ask a vibration monitoring system for

The envelope hears a bearing's knocks before the overall level doubles, and a rhythm should count only when it stands out clearly, so that chance doublings raise no warnings. It names the kind of fault, not the bearing or how bad it is. That early warning lets maintenance change a bearing in a planned stop instead of after a breakdown. Start with the machine whose stop holds up the most production.

Engineers can set up envelope warnings in five steps:

  1. List the machine's bearings with each one's designation and speed.
  2. Work out their fault frequencies in the calculator from the maker's data, or with the maker's own bearing calculator.
  3. Record a baseline, the average spectrum of the first days of normal running, and leave the sensors where they are, so later spectra compare with it.
  4. Set a warning on each rhythm for when it doubles against the baseline over several recordings and stands out clearly from the rest of the spectrum. Keep a warning on the overall values too, because as damage spreads the rhythm can fade while the overall level keeps rising.
  5. When a rhythm warns, read its envelope spectrum and the neighboring bearings' before planning the change.

The setup works when a replaced bearing shows damage on the part its rhythm named, and when over the first months few warnings come from bearings that turn out sound.

Managers buying a vibration monitoring system can ask four questions:

  1. Does it keep raw recordings, or only the overall values?
  2. Does it compute an envelope spectrum with each bearing's fault frequencies marked?
  3. Is there a sensor on each bearing housing it watches, where the ringing is strongest?
  4. What exactly raises a warning, and how does it learn each bearing's normal level?

A good supplier answers with an envelope spectrum, its fault lines marked, from one of your own bearings.

We set up vibration monitoring of bearings that computes an envelope spectrum and raises warnings for every bearing. The first step is free: send your machines' bearing designations and speeds, and we reply which faults the system can tell apart and where the sensors go.

Sources

  1. NSF I/UCR Center for Intelligent Maintenance Systems, University of Cincinnati, with Rexnord, "IMS Bearing Data", NASA Prognostics Data Repository, https://phm-datasets.s3.amazonaws.com/NASA/4.+Bearings.zip
  2. William Gousseau, Jérôme Antoni, François Girardin, Julien Griffaton, "Analysis of the Rolling Element Bearing data set of the Center for Intelligent Maintenance Systems of the University of Cincinnati", CM2016, Charenton, 2016, https://hal.science/hal-01715193
  3. Stan Muñoz Gutiérrez, Franz Wotawa, "Optimized Spectral Fault Receptive Fields for Diagnosis-Informed Prognosis", DX'25, 2025, https://arxiv.org/abs/2506.12375
  4. Hans Konstantin-Hansen, "Envelope Analysis for Diagnostics of Local Faults in Rolling Element Bearings", Brüel & Kjær application note BO0501, https://www.bksv.com/media/doc/bo0501.pdf
  5. Alan Friedman, "Jak demodulacja pomaga wczesne wykrywanie usterek łożysk" (how demodulation helps detect bearing faults early), Fluke, https://www.fluke.com/pl-pl/nauka/blog/wibracje/jak-demodulacja-pomaga-ci-wykryc-bledy-lozyska-wczesnie
  6. Delin Sirkov, "ISO 10816-3 Vibration Severity: Zones, Limits and How to Read Them", Fabrico, 2026, https://www.fabrico.io/blog/iso-10816-3-vibration-severity/
  7. NSK, "2.2 Angular Contact Ball Bearings", Bearing ABCs, https://www.nsk.com/tools-resources/abc-bearings/angular-contact-ball-bearings/

Send an enquiry

Send your machines' bearing designations and speeds. The first step is free: we reply which faults the system can tell apart on each machine and where the sensors go.

We respond within one business day.

contact@blixild.com

By submitting this form, you agree to be contacted regarding your enquiry.

← Back to the blog